Indoor Environmental Quality of Selected Flooring Materials

Authors

  • Michal Kraus Author
  • Ingrid Juhasova Senitkova Author
  • Petra Machova Author

DOI:

https://doi.org/10.29227/IM-2025-02-02-015

Keywords:

Flooring materials, Indoor Environmental Quality, TVOC emissions, Sensory evaluation, In-situ measurements

Abstract

This study investigates the influence of various flooring materials on indoor environmental quality (IEQ) through a comparative analysis based on in-situ measurements. The primary objective was to assess the concentration of total volatile organic compounds (TVOCs), perceived air acceptability, and odor intensity associated with selected flooring types, specifically wooden flooring, floating flooring, and carpet. The results demonstrated that the highest TVOC concentrations were consistently observed with carpet. However, the lowest air acceptability was recorded for wooden flooring. Notably, when wooden flooring was combined with other materials, improved sorption efficiency resulted in more favorable air acceptability outcomes than the standalone materials. Sensory evaluation of material combinations under in-situ conditions produced more favorable results than those obtained in controlled chamber tests. This suggests that real indoor environments may reduce or moderate the perceived effects of chemical emissions. Over a 36-hour monitoring period, TVOC concentrations from in-situ measurements exhibited a decreasing trend, whereas chamber test concentrations stabilized at higher levels after approximately 18 hours. After 36 hours, TVOC levels from in-situ measurements were lower than those from chamber tests for both standalone and combined flooring materials. Floating flooring demonstrated the lowest TVOC emissions and the most favorable air acceptability and odor intensity, suggesting that it provides an optimal balance between chemical emissions and sensory comfort. The findings underscore the need to complement chamber-based assessments within in-situ evaluations. Real indoor environments introduce variables — such as ventilation rates, humidity levels, and material interactions — that can significantly influence the emission behavior of materials and how these emissions are perceived. Without considering these contextual factors, indoor environmental quality assessments may overlook key aspects of real-world performance.

Author Biographies

  • Michal Kraus

    1*) Department of Civil Engineering, Faculty of Technology, Institute of Technology and Business in Ceske Budejovice, Okruzni 517/10, 370 01 Ceske Budejovice, Czech Republic; 2*) Department of Building Construction, Faculty of Civil Engineering, VSB - Technical University of Ostrava, Ludvika Podeste 1875/17, 708 00 Ostrava, Czech Republic, info@krausmichal.cz; 0000-0001-5734-1488

  • Ingrid Juhasova Senitkova

    Department of Civil Engineering, Faculty of Technology, Institute of Technology and Business in Ceske Budejovice, Okruzni 517/10, 370 01 Ceske Budejovice, Czech Republic, senitkova@mail.vstecb.cz; 0000-0003-3178-383X

  • Petra Machova

    Department of Civil Engineering, Faculty of Technology, Institute of Technology and Business in Ceske Budejovice, Okruzni 517/10, 370 01 Ceske Budejovice, Czech Republic, petra.machova@mail.vstecb.cz; 0000-0001-5749-5540