Numerical Analysis of the Magnetic Flux Leakage Field Induced by Internal Defects in Longitudinal Ferromagnetic Structures

Authors

  • Giorgi Nozadze Author
  • Nikoloz Chikhradze Author
  • Giorgi Leluashvili Author
  • Giorgi Chiqovani Author

DOI:

https://doi.org/10.29227/IM-2026-02-02-036

Keywords:

Non-Destructive Testing (NDT), Magnetic Flux Leakage (MFL), Internal Defect, Numerical Modeling, Ferromagnetic Wire Rope

Abstract

This paper discusses approaches to improving the magnetic non - destructive testing (NDT) method for longitudinal ferromagnetic bodies, leveraging the advanced simulation capabilities of modern Multiphysics engineering software. The subject of the research is steel wire ropes composed of individual wires of various shapes and cross - sections. Since steel wire ropes do not constitute a homogeneous, continuous body, the application of magnetic NDT methods encounters significant challenges. This is primarily manifested in the difficulty of reliably detecting the magnetic flux leakage (MFL) field generated by wire breakages, as the discrete, multi - wire structure of the rope increases background electromagnetic noise and complicates the extraction of the useful signal. Although modern flaw detectors partially address this issue, the reliable registration of internal wire breaks remains a critical challenge to this day. In this work, the numerical calculation of the MFL field intensity resulting from an internal breakage within a simplified, two - layer steel wire structure is modelled in an engineering software environment. The spatial distribution of the leakage field induced by defects of varying widths and depths is investigated both within the ferromagnetic medium itself and in the surrounding atmospheric environment. The latter is of particular importance for practical NDT applications, given that magnetic sensing devices are typically positioned outside the ferromagnetic component. Based on the obtained results, it can be concluded that the utilization of modern engineering software tools enables a detailed and highly reliable study of the detection and registration processes for internal defects in ferromagnetic wire structures. In the future, developing an accurate geometric model of real steel wire ropes and conducting simulation studies will allow for the precise numerical computation of the MFL field spatial distribution, thereby establishing a foundation for the optimization and refinement of magnetic sensor mechanisms.

Author Biographies

  • Giorgi Nozadze

    Grigol Tsulukidze Mining Institute, 7 Mindeli Street, Tbilisi 0186, Georgia; E - mail: g.nozadze@mining.org.ge; ORCID: 0009 - 0004 - 9419 - 3882

  • Nikoloz Chikhradze

    Grigol Tsulukidze Mining Institute, 7 Mindeli Street, Tbilisi 0186, Georgia, Georgian Technical University, 77, Kostava street, 0160, Tbilisi, Georgia ; E - mail: chikhradze@mining.org.ge; ORCID: 0000 - 0001 - 5369 - 5123

  • Giorgi Leluashvili

    Georgian Technical University/Grigol Tsulukidze Mining Institute, 7, E. Mindeli Street, Tbilisi 0186, Tbilisi, Georgia; E - mail: Giorgileluashvili777@gmail.com; ORCID 0009 - 0004 - 5683 - 7544

  • Giorgi Chiqovani

    Tbilisi State University/EMCoS LLC , 27 Pekini Str.160 Tbilisi, Georgia, E - mail: giorgi.chiqovani @emcos.com

References

1. K. Feyrer, Wire Ropes: Tension, Endurance, Reliability, 2nd ed. Berlin, Germany: Springer - Verlag, 2015.

2. I. M. L. Ridge, "Degradation and endurance of wire ropes in industrial applications," Key Engineering Materials, vol. 413, pp. 543 - 550, 2009.

3. J. Blitz, Electrical and Magnetic Methods of Non - destructive Testing. London, UK: IOM Communications, 1991.

4. J. Zhang, S. Liu, and H. Wang, "Structural background noise reduction techniques in magnetic flux leakage testing of multi - wire steel ropes," Journal of Magnetism and Magnetic Materials, vol. 485, pp. 204 - 213, Sep. 2019.

5. D. L. Atherton, "Magnetic flux leakage as applied to inspection of pipelines," IEEE Transactions on Magnetics, vol. 31, no. 5, pp. 4142 - 4147, Sep. 1995.

6. Y. Cao, J. Zhang, and X. Wang, "Analytical and numerical analysis of magnetic flux leakage for discrete steel wire rope inspection," NDT & E International, vol. 87, pp. 71 - 82, Apr. 2017.

7. ASTM E1571 - 21, Standard Practice for Electromagnetic Examination of Ferromagnetic Steel Wire Rope, ASTM International, West Conshohocken, PA, 2021.

8. J. B. Nestleroth and T. A. Bubenik, Magnetic Flux Leakage Technology, Columbus, OH: Nondestructive Testing Information Analysis Center (NTIAC), 1999.

9. H. Wang, S. Liu, and Y. Cao, "Investigation on the magnetic shielding effect and internal wire break detection in steel wire ropes using MFL sensors," Sensors and Actuators A: Physical, vol. 321, p. 112590, Apr. 2021.

10. P. P. Silvester and R. L. Ferrari, Finite Elements for Electrical Engineers, 3rd ed. Cambridge, UK: Cambridge University Press, 1996.

11. Y. Sun, S. Liu, and J. Zhang, "Numerical simulation and optimisation of magnetic flux leakage testing for cylindrical ferromagnetic steel rods," Research in Nondestructive Evaluation, vol. 29, no. 4, pp. 185 - 199, July 2018.

12. S. Liu, Y. Cao, and H. Wang, "Three - dimensional finite element modelling of magnetic flux leakage signals induced by subsurface defects in ferromagnetic bars," IEEE Transactions on Magnetics, vol. 56, no. 3, pp. 1 - 8, Mar. 2020.

Published

2026-11-01

Most read articles by the same author(s)